Direct vent fireplace repair for Davie homes
Draft problems on natural-draft units are checked at the draft hood and traced to their cause.
- Owned and run locally
- Available for same-day service
- Fully licensed and insured
- Family owned and run
Gas venting faults we are asked about
- Nest or leaves at the outside cap
- Rust on exposed vent pipe
- A porch enclosed around the termination
- Rattling cap on a windy day
Jump to
How we assess and repair gas vents
Where Type B vent must not be used
The same vent maker is clear about what Type B vent is not for. It should not serve appliances that need a pressure-tight or liquid-tight vent, or wall furnaces listed only for other vent types. Appliances that can readily be converted to solid or liquid fuels are excluded too.
If we find Type B vent serving an appliance its instructions exclude, we explain the mismatch and why it matters. The fix usually involves the vent system the appliance manual actually calls for. That work is quoted as a vent replacement, with the appliance kept off until it is done.
Unlisted decorative shrouds over the cap
Decorative shrouds and covers over terminations are allowed only when listed for the vent system. One manual adds that a decorative cover can increase the clearances the cap needs, and refers to the shroud's own instructions.
If a termination has been fitted with a homemade cover or one from another product, we explain why it should come off. The listed decorative cap for your system can be quoted instead, with its clearances checked. We do not leave an unlisted cover on a vent we have worked on.
Bracing a tall vent above the roof
A gas vent that stands well above the roof can move in the wind, stressing its joints and the flashing below. One vent maker asks for tall vents to be securely braced and warns against attaching the bracing to the cap.
We check whether a tall roof termination is braced as its instructions require and whether the bracing is attached to the pipe rather than the cap. Missing or failed bracing is replaced with the parts the vent maker lists. The roof seal is checked at the same time, because movement often shows there first.
When the vent system is no longer made
Vent systems are sometimes discontinued, and replacement sections may become hard to find. Because the manuals prohibit mixing systems, a missing part cannot simply be swapped for a similar one from another maker.
If the original system is no longer available, we check the appliance manual for other approved vent systems. Where one is listed, the affected run may need replacing from the appliance to the termination with the new system. We explain the extent of that work before quoting it.
The gas venting scope you approve
- Concealed sections recorded as not seen
- Attic insulation shield position
- Separate vent confirmed for the appliance
- Operating check after the vent work
Questions on gas vents, answered for Davie
Why does direct-vent pipe have an inner and outer pipe?
A direct-vent system usually runs one pipe inside another. Outside air for the fire comes in through one passage and exhaust leaves through the other, and both stay sealed from the room, which is why each joint and gasket matters.
Is a decorative shroud allowed over the termination?
Only a listed decorative cap or shroud made for your vent system. The manuals warn that decorative covers can change the clearances a cap needs, so we check the listing and the clearances before fitting one.
What happens to the old vent parts you remove?
We take them away with the other debris, which is cleaned up and hauled away before we leave. If you would like to see or keep a damaged section, say so and we will set it aside for you.
We received your request
Our team will contact you to arrange your inspection.
Chimney & Fireplace Brands We Work With
DuraVent 
Olympia Chimney and Venting Copperfield Chimney Supply 
Rutland Heatilator Heat & Glo