Gas fireplace vent repair and replacement in Kendale Lakes
A vent fault is traced along the whole route, from the appliance collar to the termination.
- Owned and run locally
- Available for same-day service
- Fully licensed and insured
- Family owned and run
Outside and inside signs of gas vent trouble
- Plants grown over the termination
- Water marks around the wall penetration
- Flashing lifted around a roof vent
- A porch enclosed around the termination
Jump to
Gas vent pipes, joints and terminations
Shutdowns that trace back to the vent
Some appliances shut themselves down when the vent is not working as it should. One vent maker notes that fan-assisted appliances are designed to shut down when they detect excessive pressure at the outlet, which can indicate the system is not venting properly.
A fireplace that shuts down may have an appliance fault, a supply issue or a vent problem. We check the vent route, termination and joints alongside the appliance findings. If the evidence points to the vent, the repair is quoted under venting. Appliance faults found along the way go to our repair service.
Spillage at the draft hood
On a natural-draft appliance, the draft hood relief opening should draw air in while the unit runs. If combustion products spill out of that opening instead, the vent is not drawing properly. One manual warns that negative pressure can cause spillage of combustion fumes and soot.
We carry out a draft check at the draft hood after the unit has warmed up, following the vent maker's method. If it shows spillage, the fireplace stays off while we trace the cause, which may sit in the vent, the termination, the house pressure or the appliance.
Safety checks before and after vent work
Looking for spillage, blockage, restriction, leakage and corrosion is how one installation manual frames the safety check it wants ahead of and after power vent work. The same thinking applies to any vent repair.
Before we start, we record the condition of the route and the appliance's behavior. After the work, we check the route again, run the appliance and confirm the vent is doing its job. Both checks go on the written record, so you can see what changed.
The written record of the vent work
Every vent visit closes with a written record of the work. On it are the appliance, the vent maker and system, the route as far as it could be seen, the parts replaced, the checks made and any draft results.
It also notes what stayed concealed and any limits we placed on use. Keep the record with the appliance manual. The next person to work on the vent can see which sections were replaced, which were checked and which could not be reached.
Line items for gas vent work
- Route traced from collar to termination
- Termination cap condition and fastening
- Attic insulation shield position
- Gas vent inside a masonry chimney reviewed
What people ask about gas vents
Why does direct-vent pipe have an inner and outer pipe?
A direct-vent system usually runs one pipe inside another. Outside air for the fire comes in through one passage and exhaust leaves through the other, and both stay sealed from the room, which is why each joint and gasket matters.
What is a draft check on a natural-draft fireplace?
After warm-up, a test at the draft hood relief opening shows which way the exhaust is moving, up the vent or back out into the room. We carry it out during vent work on draft-hood appliances.
Do you move a termination if clearances are no longer met?
We can relocate it within the vent tables for the appliance, using listed parts. If no permitted position exists nearby, we explain the options, including changes to the nearby feature by the appropriate trade.
We received your request
Our team will contact you to arrange your inspection.
Chimney & Fireplace Brands We Work With
DuraVent 
Olympia Chimney and Venting Copperfield Chimney Supply 
Rutland Heatilator Heat & Glo