Vent-free gas fireplace service for Surfside homes

A clear diagnosis, a written estimate and work only on the items you approve.

  • Owned and run locally
  • Available for same-day service
  • Fully licensed and insured
  • Family owned and run

What changes in a ventless unit before a repair

  • Pilot lights but burner will not
  • No spark at the pilot
  • Uneven or delayed burner lighting
  • Pilot hard to light after gas work
Jump to

Ventless fireplace repair, explained step by step

The manual shutoff valve ahead of a vent-free unit

Vent-free manuals call for a manual shutoff valve in the supply line ahead of the gas control. Service work uses it to isolate the unit. Knowing where yours sits helps on the day of the visit.

If you do not know where it is, tell us and we will point it out. We do not install or move supply piping, which is work for a gas contractor. We do check that the valve works for the service we are doing, and we note its location in the written record.

Delayed or rough lighting of a vent-free burner

The main burner should light smoothly across its length. A delay followed by a soft thump, or flame that rolls out, is worth a call. The manuals list causes such as blocked ports, a log or ember near the pilot and low pressure.

Stop using the unit until it is checked. We clear the ports, reset any piece that blocks the path from pilot to burner and confirm pressure. Then we light it several times while you watch, so you can see the smooth lighting the manual describes.

The screen in front of a vent-free fire

Vent-free manuals expect a screen in place while the unit burns. The screen keeps hands and objects away from the flame, and it has openings that let combustion air reach the burner. A solid panel in its place changes the air the flame gets.

We check that the screen fits, is not damaged and does not block air. If it was removed during cleaning or a renovation, we put it back. Where a replacement is needed, it comes from the maker or matches what the manual describes.

Where vent-free logs may run only as vented

One log set manual notes that some codes allow its burner to run only in a vented mode, with the damper open. The code in force for your home governs that choice, not the maker's brochure. The installation should have been set up to match.

We check how your set is being run and what its manual allows. If the unit is running vent-free where only vented use is allowed, we explain that and what would need to change. Questions about how a rule applies can also go to your local building department.

Ventless log and pilot items on the estimate

  • Pilot supply line cleared where specified
  • Ceramic media level in the burner
  • Screen and liner panels inspected
  • Bedroom or bathroom location review

Vent-free gas logs and pilots, answered

Do vent-free logs have to sit in exact positions?

Yes. Each set comes with a placement diagram, and the flames are meant to rise between the logs. A log out of place can cause soot and poor combustion. We reset every piece to the diagram and check the flame before we leave.

Is a vent-free unit meant to heat the whole house?

No. The Florida fuel gas code says unvented room heaters may not be the sole source of comfort heating in a home, and the manuals call them supplemental. They warm a room, with that room's air and volume in mind.

Why is there moisture on the windows when it runs?

Burning gas produces water vapor, and a vent-free unit releases it into the room. More condensation than usual can suggest the unit is large for the space or short of fresh air. We check both against the manual.